MODEL SPECS
- 3-cylinder diesel engine
- Permanent magnet alternator
- Pure sine wave output
- Digital voltage regulation w/no adjustments required
- Bottom air inlet and outlet
- Integral enclosed muffler with stationary exhaust pipe connection point
- USDA-approved spark arrestor
- Internal radiator
- Sound-insulated cover with cooling air inlet and outlet ducts
- Intake silencer
- Heavy-duty air cleaner
- Maintenance-free electronic governor
- Fused DC circuits
- Meets applicable U.S. EPA and California emissions standards
- Waterproof connector for remote operation
- Focalized mounting system
- Overvoltage, low oil pressure, over temp, over speed and overload safeties
- Bulkhead type connections for fuel and battery
- Terminal block connection for AC output
- Electric fuel pump
- Full flow oil and fuel filter
- Service and maintenance from below
- Automatic timed glow plugs for quick, easy start
- Instant one-touch stop
- Hour meter
Model Ratings
| Models | Fan | Hz | Watts | Voltage | Amps | Phase | Circuit Breaker |
| 6.0 HDKAH-1044 | Internal | 60 | 6000 | 120 | 50 | 1 | 30 A, 2-pole |
Specification sheet
Operator manual
Ambient conditions for rated power output with muffler and RV enclosure, per ISO 8528-1:
- Temperature: 77° F (25° C)
- Altitude: 500 ft (152.4 m), (99 kPa dry)
Typical power output change based on ambient conditions:
- Temperature: Power output decreases 1% for every 10° F (5.5° C) increase
- Altitude: Power output decreases 3.5% for every 1000 ft (305 m) increase
Ratings represent minimums. Actual performance may be significantly higher based on installation and operating conditions.
Weight, Size & Sound Levels
| Weight | 420 lbs | (191 kg) |
| Length | 36.3 in | (922 mm) |
| Width | 23.6 in | (599 mm) |
| Height | 22.3 in | (566 mm) |
| Sound | 66 dB(A) | (readings at 10 ft (3 m) half load) |
- Meets National Park Service sound level requirements (60 dB(A) @ 50ft) for national park use. - Typical installation will further reduce sound level. Model Ratings| Models | Fan | Hz | Watts | Voltage | Amps | Phase | Circuit Breaker | | 6.0 HDKAH-1044 | Internal | 60 | 6000 | 120 | 50 | 1 | 30 A, 2-pole |
Specification sheet Operator manual
Ambient conditions for rated power output with muffler and RV enclosure, per ISO 8528-1: - Temperature: 77° F (25° C) - Altitude: 500 ft (152.4 m), (99 kPa dry) Typical power output change based on ambient conditions: - Temperature: Power output decreases 1% for every 10° F (5.5° C) increase - Altitude: Power output decreases 3.5% for every 1000 ft (305 m) increase Ratings represent minimums. Actual performance may be significantly higher based on installation and operating conditions WarrantyThis limited warranty covers virtually everything except routine maintenance for the first two years you own your RV generator set, and covers parts and labor on major power train and generator set parts during the third year. In addition, it also includes a free 90-day adjustment policy, which provides that Cummins Inc. will make minor adjustments during the first three months you own it – free of charge! Please note: This 3-year limited warranty applies to RV generator sets used in RV applications only, and does not apply to RV generator sets used in commercial mobile applications. manufacturer's limited warranty
|